SABER Certificate forElectrical Cables
Power, Control & Fire-Resistant Cables
Get product-specific HS classification and certification guidance for power, control and fire-performance cable.

- CertificatePCoC / SCoC*Product Certificate of Conformity & Shipment Certificate
- PCoC CostUSD 300
- Processing Time2–3 Working Days
- SADAD FeesPaid by Importer
Product & Regulation
HS Code
HS 8544
Insulated wire and cable. Terminations and joints supplied with it fall under 8536 or 8535 by voltage. The Saudi code runs longer than four digits and is confirmed from the specification, not from the product name.
Regulation
IEC 60502 family / IEC 60840 / IEC 62067 where relevant; classification review
Candidate review point, not a declaration that this route applies. Confirmed against the current regulation and model scope before anything is claimed.
Product
Rated voltage, conductor, insulation and termination
What the assessment reads the product as, which decides the evidence it asks for.
Types of Electrical Cables
Low voltage power cables
PVC and XLPE insulated cable for distribution and fixed installation, classified by conductor, cross-section and voltage rating.
Medium & high voltage cables
Cable above 1 kV, declared as a U0/U voltage class. Type test evidence is tied to the class, and terminations are separate products.
Control & instrumentation cables
Multicore, screened and pair or triad cable, where core count is part of the construction and the screen changes the test programme.
Fire-resistant cables
Cable declared to keep a circuit energised through a fire for a stated duration. The duration is a tested figure, not a design intention.
Low-smoke and zero-halogen cables
A reaction-to-fire claim about what the cable emits while burning — measured separately from any circuit-integrity claim.
Flexible cords and building wire
Flexible cable for appliances and portable equipment, and single-core wire for fixed building installation.
Each type is confirmed on its own classification and evidence. Which of them a single certificate can cover depends on how closely the constructions and test reports match.
Documents Required
- Lab Test Report(No report? We can arrange testing.)
- Commercial Invoice
- Packing List
The core set. On this family the file also turns on voltage ranges, conductor sizes, type test and routine test evidence. Which further documents apply varies with the confirmed classification and the model scope, so the full list is issued per file rather than per category.
Sample Certificate
Illustrative layout only — not an issued certificate, and not a reproduction of one. Certificates are issued by approved conformity assessment bodies, not by BenzilaCert.
Application Examples
Typical files in this product family and the support they call for. Illustrative scenarios, not completed engagements.
- Example 01
Medium-voltage cable
A distribution cable declared as a U0/U voltage class, where the type tests are checked against the construction and cross-section range actually supplied.
- Example 02
High-voltage cable
A transmission-class supply, where a utility or project specification may lead instead of the general product regulation, and accessories are separate products.
Get Your SABER Certificate
Send the Saudi HS Code if you have it, the product specification and a commercial invoice, and we will come back with the likely route and what is missing.
* Where applicable. Timelines and charges shown are indicative and subject to documentary review, and government and SADAD fees are separate from conformity body, testing and consultancy charges. The applicable Saudi regulation and the exact HS code must be confirmed from the product specification against the current SABER and ZATCA classification.
BenzilaCert is an independent consultancy providing application and documentation support. It is not SASO, SABER or a certificate-issuing authority, and does not issue conformity certificates.