SABER Certificate forWater Heaters & Hot-Water Equipment

Electric Storage, Instantaneous, Gas, Solar & Heat Pump Water Heaters

How the water is heated decides the route. An electric heater is an appliance with an energy declaration behind it; a gas-fired one leaves that route entirely for a combustion assessment. We sort the catalogue by heat source before anything else.

A horizontal cylindrical electric storage water heater with two brass water connections and a control knob on its end face, a steel wall bracket lying alongside
  • CertificatePCoC / SCoC*Product Certificate of Conformity & Shipment Certificate
  • PCoC CostUSD 300
  • Processing Time2–3 Working Days
  • SADAD FeesPaid by Importer

Product & Regulation

HS Code

HS 8516

Electric instantaneous or storage water heaters and immersion heaters. A gas-fired instantaneous or storage heater falls under 8419 instead, and a heat-pump water heater can classify with refrigerating machinery under 8418. The Saudi code runs longer than four digits and is confirmed from the heat source and the specification, not from the product name.

Regulation

Electrical safety for the electric types with an energy efficiency declaration for the regulated sizes; a separate gas appliance assessment where the heat source is combustion; storage vessel and safety device requirements alongside. Applicable set confirmed per heat source

Candidate review point, not a declaration that this route applies. Confirmed against the current regulation and model scope before anything is claimed.

Product

Electric storage or instantaneous heater, gas-fired heater, solar system, or heat-pump water heater

What the assessment reads the product as, which decides the evidence it asks for.

Types of Water Heaters & Hot-Water Equipment

  • Electric storage heaters

    Wall and floor-standing cylinders with an immersion element. Standing loss dominates the energy figure, so insulation decides the result.

  • Instantaneous electric heaters

    Tankless heaters and electric showers. No stored volume, so the rated input and the flow switch carry the assessment.

  • Gas-fired water heaters

    Instantaneous and storage gas heaters. Combustion, gas family and flueing move these off the electrical route entirely.

  • Solar water heating systems

    Collector and tank systems, thermosiphon or pumped. Assessed as a system, with any electric backup element declared too.

  • Heat pump water heaters

    Units making hot water from a refrigerant circuit. Treated as refrigerating machinery, so the refrigerant charge comes into the file.

  • Tanks, elements and safety devices

    Storage vessels, immersion elements, thermostats, cut-outs and relief valves. A pressurised vessel question beside the electrical one.

Each type is confirmed on its own classification and evidence. Which of them a single certificate can cover depends on how closely the constructions and test reports match.

Documents Required

  • Product Details & Model List(every model with its heat source, capacity and rated input)
  • Datasheet & Manufacturer Details
  • Lab Test Report(No report? We can arrange testing.)
  • Commercial Invoice & Packing List(needed at the shipment stage, not to start)

The core set. On water heaters the file also turns on the heat source, the storage capacity and rated input, the energy figure declared and the test it came from, the tank lining and working pressure, the temperature cut-out and relief valve fitted, and for gas types the gas family and flue arrangement. Which further documents apply varies with the confirmed classification and the model scope, so the full list is issued per file rather than per category.

Sample Certificate

Illustrative layout only — not an issued certificate, and not a reproduction of one. Certificates are issued by approved conformity assessment bodies, not by BenzilaCert.

Application Examples

Typical files in this product family and the support they call for. Illustrative scenarios, not completed engagements.

  • Example 01

    Manufacturer with a mixed heater catalogue

    An illustrative maker listing electric storage heaters in six capacities and two gas-fired models. The electric range groups by capacity for the energy declaration; the gas models are filed as a separate family.

  • Example 02

    Importer shipping heaters for a hotel fit-out

    An illustrative consignment of storage heaters with spare elements and relief valves. The appliances, the spare parts and the energy declaration are each handled before the shipment certificate.

Get Your SABER Certificate

Send the Saudi HS Code if you have it, the product specification and a commercial invoice, and we will come back with the likely route and what is missing.

WhatsApp: +91 91300 30031No Advance Payment | Available 24/7

* Where applicable. Timelines and charges shown are indicative and subject to documentary review, and government and SADAD fees are separate from conformity body, testing and consultancy charges. The applicable Saudi regulation and the exact HS code must be confirmed from the product specification against the current SABER and ZATCA classification.