SABER Certificate forFire-Resistant Building Systems

Fire Stopping, Cavity Barriers, Board Encasement, Intumescent Coatings & Rated Partitions

Passive fire protection has no rating on its own. The hours belong to a tested construction — a named wall, a named service through it, sealed a named way — so the product you ship is a component of that test. We establish which construction the rating comes from before the datasheet is taken at face value.

A short upright section of fire-rated partition with its plasterboard face cut back diagonally to show the galvanised steel studs in their bottom track and a mineral wool batt in the bay between them, with a loose board offcut leaning against the finished face
  • CertificatePCoC / SCoC*Product Certificate of Conformity & Shipment Certificate
  • PCoC CostUSD 300
  • Processing Time2–3 Working Days
  • SADAD FeesPaid by Importer

Product & Regulation

HS Code

HS 3214

Mastics, sealing compounds and non-refractory surfacing preparations, which is where fire sealant and intumescent mastic sit. An intumescent paint falls under 3208 or 3209, a gypsum fire board under 6809, a mineral wool batt or cavity barrier under 6806, a rated glazing pane under 7007 and a steel pipe collar or damper under 7326 or 8481, so one passive fire package routinely spans five headings. The Saudi code runs longer than four digits and is confirmed from the composition and the declared function, not from the product name.

Regulation

Fire resistance requirements expressed for a tested construction rather than for the product alone, covering the integrity, insulation and where relevant load-bearing period achieved in a named assembly, with reaction to fire classification evidenced separately for the material and civil defence approval applying to the installed works; candidate pending verification

Candidate review point, not a declaration that this route applies. Confirmed against the current regulation and model scope before anything is claimed.

Product

An inert passive fire protection product supplied as a component of a tested construction — a penetration seal, cavity barrier, joint seal, board encasement, applied coating, rated glazing or damper. Active detection and suppression equipment and complete rated doorsets are different product classes

What the assessment reads the product as, which decides the evidence it asks for.

Types of Fire-Resistant Building Systems

  • Penetration seals, collars and wraps

    Intumescent pipe collars, pipe wraps, cable transit seals, mortar and pillows. Rated only for a stated service diameter through a stated wall build, so the pipe decides the product.

  • Cavity barriers and linear joint seals

    Cavity barriers in facades and ceiling voids, head-of-wall and movement joint seals. The weakest line in a compartment is usually a joint rather than a surface.

  • Rated partitions, shafts and board encasement

    Fire-rated stud partitions, riser and shaft linings and board encasement to steel and ducts. The layer count, board type and stud spacing are the certified construction, not suggestions.

  • Intumescent and sprayed protection to steel

    Thin-film intumescent coatings and sprayed cementitious protection. Thickness is calculated from the section factor and the period needed, so two beams on one job take two thicknesses.

  • Fire-rated glazing and glazed screens

    Integrity-only and insulating rated glass with its framing, beads and seals. The pane is never certified alone — the glazing system it sits in is what was tested.

  • Fire and smoke dampers and ductwork protection

    Mechanical and motorised dampers and rated duct enclosure. A motorised damper carries an actuator, which puts one electrical product inside an otherwise passive package.

Each type is confirmed on its own classification and evidence. Which of them a single certificate can cover depends on how closely the constructions and test reports match.

Documents Required

  • Product Details & Model List(with the tested construction each rating is claimed from)
  • Datasheet & Manufacturer Details
  • Lab Test Report(No report? We can arrange testing.)
  • Commercial Invoice & Packing List(needed at the shipment stage, not to start)

The core set. On passive fire protection the file also turns on the tested construction the rating comes from — the supporting wall or floor type and thickness, the service type and diameter passing through it, the orientation and the seal detail — the integrity and insulation period claimed, the reaction to fire classification of the material, and for applied protection to steel the section factor and the dry film thickness calculated for it rather than a single nominal figure. Which further documents apply varies with the confirmed classification and the model scope, so the full list is issued per file rather than per category.

Sample Certificate

Illustrative layout only — not an issued certificate, and not a reproduction of one. Certificates are issued by approved conformity assessment bodies, not by BenzilaCert.

Application Examples

Typical files in this product family and the support they call for. Illustrative scenarios, not completed engagements.

  • Example 01

    Contractor sealing a riser penetration

    An illustrative contractor importing collars, wraps and sealant for services crossing a rated riser wall. Each product is matched to the wall build and the pipe diameter it was tested against, because the hours belong to that pairing.

  • Example 02

    Applicator importing intumescent coating

    An illustrative applicator bringing in one intumescent coating for a steel frame with several section sizes. One product and several thicknesses, since the section factor rather than the tin sets the figure.

Get Your SABER Certificate

Send the Saudi HS Code if you have it, the product specification and a commercial invoice, and we will come back with the likely route and what is missing.

WhatsApp: +91 91300 30031No Advance Payment | Available 24/7

* Where applicable. Timelines and charges shown are indicative and subject to documentary review, and government and SADAD fees are separate from conformity body, testing and consultancy charges. The applicable Saudi regulation and the exact HS code must be confirmed from the product specification against the current SABER and ZATCA classification.
BenzilaCert is an independent consultancy providing application and documentation support. It is not SASO, SABER or a certificate-issuing authority, and does not issue conformity certificates.